<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-02 06-07-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 41 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 68 kHz 4159 0,0240
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,5 dBr 5,30 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 68 kHz MIN: 14 kHz % above 76 kHz: 0,0240 Acquired: 2026/05/02 6.06.15 Total samples: 4159 Equivalent time: 0:03:27 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 5,9 dBr MIN: 3,5 dBr AVE: 5,30 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2026/05/02 6.06.15) 05.52 05.54 05.56 05.58 06.00 06.02 06.04 06.06 0 2 4 6 Pm [dBr]